- SECTION 07410
-
- METAL ROOF AND WALL PANELS
-
- NOTE ** This section is based on preformed metal roof,
- wall, ceiling and soffit systems manufactured by
- ATAS International, Inc. Headquartered in
- Allentown, PA, ATAS also has a satellite
- manufacturing, service and warehouse facility in
- San Diego, California. ATAS produces many
- different types of preformed and prefinished
- enclosure systems in both aluminum and
- galvanized/Galvalume(R) steel for varied
- applications.
- NOTE **
- NOTE ** For more information or design assistance, contact
- ATAS as follows:
- NOTE ** ATAS International, Inc.
- NOTE ** 6612 Snowdrift Road
- NOTE ** Allentown, PA 18106
- NOTE ** Telephone: 610-395-8445; FAX: 610-395-9342
- NOTE **
- NOTE ** ATAS also has a catalog by Fax program, available
- on a 24-hour basis. Call 1-800-4-FAXCAT, follow
- the prompts, enter the code name for the product
- you are interested in, and ATAS will fax you
- pertinent data. FAXCAT Codes are indicated in the
- notes for each product.
- NOTE **
- NOTE ** SECTION 07410 - METAL ROOF AND WALL PANELS,
- Copyright 1997, The Architect's Catalog, Inc.
- NOTE ** ATAS's capable staff is able to assist in the
- design or provide shop drawings for your project.
- Final choice of materials and installation is the
- responsibility of the owner, architect and/or the
- owner's agent. ATAS International, Inc. cannot be
- held responsible for the ultimate selection or the
- installation of those materials. Due to slight
- stresses created by a variety of conditions, from
- atmospheric to installation, the panel may have a
- wavy appearance (oilcanning) after installation.
- The greater the flat area of the panel, the greater
- the potential for slight imperfections to be
- noticed. This condition is beyond ATAS
- International's control, consequently, oilcanning
- or distortion of the product is not a valid reason
- for rejection of the materials. Should any
- manufacturing defects occur, ATAS International can
- only be held responsible for the replacement of
- materials. ATAS reserves the right to modify,
- eliminate and/or change its products without prior
- notification.
-
- PART 1 GENERAL
-
- 1.1 SECTION INCLUDES
- NOTE ** Delete items below not required for project.
-
- A. Preformed aluminum roof panels.
-
- B. Preformed steel roof panels.
-
- C. Preformed aluminum wall panels.
-
- D. Preformed steel wall panels.
-
- E. Preformed aluminum ceiling and soffit system.
-
- F. Flashings, fasteners, and accessories as required for
- weatherproof installation.
-
- 1.2 RELATED SECTIONS
- NOTE ** Delete any sections below not relevant to this
- project; add others as required.
-
- A. Section 05120 - Structural Steel: Building frame.
-
- B. Section 05400 - Cold Formed Metal Framing: Exterior stud
- wall framing system.
-
- C. Section 07220 - Roof Insulation.
-
- D. Section 07260 - Vapor Retarders.
-
- E. Section 07620 - Sheet Metal Flashing and Trim.
-
- F. Section 07900 - Joint Sealers.
-
- G. Section 08520 - Aluminum Windows.
-
- H. Section 13121 - Pre-Engineered Buildings: Building
- framing system.
-
- 1.3 REFERENCES
- NOTE ** Delete references from the list below that are not
- actually required by the text of the edited
- section.
-
- A. AA DAF-45 - Designation System for Aluminum Finishes; The
- Aluminum Association, Inc.
-
- B. AAMA 607.1 - Voluntary Guide Specification and Inspection
- Methods for Clear Anodic Finishes for Architectural
- Aluminum; American Architectural Manufacturers
- Association.
-
- C. AAMA 608.1 - Voluntary Guide Specification and Inspection
- Methods for Electrolytically Deposited Color Anodic
- Finishes for Architectural Aluminum; American
- Architectural Manufacturers Association.
-
- D. ASCE 7 - Minimum Design Loads for Buildings and Other
- Structures; American Society of Civil Engineers.
-
- E. ASTM A 653/A 653M - Standard Specification for Steel
- Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated
- (Galvannealled) by the Hot-Dip Process.
-
- F. ASTM A 755/A 755M - Standard Specification for Steel
- Sheet, Metallic Coated by the Hot-Dip Process and
- Prepainted by the Coil Coating Process for Exterior
- Exposed Building Products.
-
- G. ASTM B 209 - Standard Specification for Aluminum and
- Aluminum-Alloy Sheet and Plate.
-
- H. ASTM B 370 - Standard Specification for Copper Sheet and
- Strip for Building Construction.
-
- I. ASTM E 283 - Standard Test Method for Determining the
- Rate of Air Leakage Through Exterior Windows, Curtain
- Walls, and Doors Under Specified Pressure Differences
- Across the Specimen.
-
- J. ASTM E 331 - Standard Test Method for Water Penetration
- of Exterior Windows, Curtain Walls, and Doors by Uniform
- Static Air Pressure Difference.
-
- K. ASTM E 1592 - Standard Test Method for Structural
- Performance of Sheet Metal Roof and Siding Systems by
- Uniform Static Air Pressure Difference.
-
- L. UL 580 - Standard for Tests for Uplift Resistance of Roof
- Assemblies.
-
- 1.4 PERFORMANCE REQUIREMENTS
-
- A. Roof Panel System: Provide roof system with performance
- as specified when installed, designed in accordance with
- applicable codes.
-
- B. Provide structural performance appropriate to substrate
- over which roof system is installed.
-
- C. Wind Resistance:
- NOTE ** Delete all but one of the following three
- definitions of design wind loads.
- 1. Design and size components to withstand loads caused
- by wind pressures as follows:
- a. Positive pressure: ___ psf (___ kPa) normal to
- panel.
- b. Negative pressure: __ psf (___ kPa) normal to
- panel.
- 2. Design and size components to withstand loads caused
- by wind pressures as specified in ASCE 7.
- 3. Design and size components to withstand loads caused
- by wind pressures as specified in applicable code.
- 4. Provide UL 90 rated system tested in accordance with
- UL 580.
- 5. Provide report of test conducted in accordance with
- ASTM E 1592, showing that panel system and anchorage
- to be used will withstand these design pressures.
- 6. Provide clip fastener pull-out test report and
- calculations.
- NOTE ** Delete one of the following two paragraphs,
- describing deflection.
-
- D. Maximum Deflection under Design Loads: 1/180 of span.
-
- E. Maximum Deflection under Design Loads: 1/240 of span.
-
- F. System Movement: Accommodate movements due to thermal
- expansion and contraction, dynamic loading, and
- deflection of structural support system without damage to
- panel system or loss of weatherproofing capability.
-
- G. Air Infiltration: Maximum ____ cfm per square foot when
- system is tested in accordance with ASTM E 283 at a
- static pressure of ___ psf (___ kPa).
-
- H. Water Penetration: No uncontrolled water leakage when
- system is tested in accordance with ASTM E 331 at static
- water pressure of ___ psf (___ kPa).
-
- I. Drainage: Provide positive drainage to exterior for
- moisture entering building enclosure or condensation
- occurring within exterior building envelope.
-
- 1.5 SUBMITTALS
-
- A. Submit under provisions of Section 01300.
-
- B. Manufacturer's Certifications:
- 1. Certified statement from panel manufacturer
- documenting manufacturer qualifications.
- 2. Certified statement from panel manufacturer that
- panels are tension-leveled during the roll-forming
- process.
-
- C. Product Data: Manufacturer's current product
- specifications and installation instructions.
-
- D. Shop Drawings: Include small scale roof plan and
- elevations, as required. Show details of trim and
- flashing conditions, fastening and anchorage methods,
- weatherproofing techniques, terminations, and
- penetrations.
-
- E. Selection Samples: Submit actual metal chips with full
- range of colors available for Architect's selection.
-
- F. Verification Samples: Submit two samples of each type of
- metal panel required, not less than 12 inches (305 mm),
- and illustrating finished panel profile, color, sheen,
- and texture.
-
- G. Test Reports: Submit copies of test reports verifying:
- 1. Wind load performance of panels and anchors.
- 2. Air infiltration performance.
- 3. Water penetration performance.
- 4. Coating quality.
-
- 1.6 QUALITY ASSURANCE
-
- A. Manufacturer Qualifications: Minimum of 10 years of
- experience in factory-fabrication and roll-forming of
- metal roof panels.
-
- B. Installer Qualifications: Company specializing in the
- type of work required for this project, with not less
- than 2 years of documented experience.
-
- C. Pre-Installation Meeting: Convene meeting not less than
- one week prior to beginning installation.
-
- 1.7 DELIVERY, STORAGE, AND HANDLING
-
- A. Comply with provisions of Section 01600.
-
- B. Order materials based on field measurements, not on
- construction drawings.
-
- C. Package panels at factory.
-
- D. Coordinate delivery schedule with installation schedule.
- Do not deliver materials of this section to project site
- until suitable facilities for storage and protection are
- available.
-
- E. Protect materials from damage during transit and at
- project site. Store under cover but sloped to provide
- positive drainage. Do not expose materials with
- strippable protective film to direct sunlight or extreme
- heat.
-
- F. Do not allow storage of other materials or allow staging
- of other work on installed metal panel roof system.
-
- 1.8 WARRANTY
-
- A. Comply with provisions of Section 01780.
- NOTE ** Retain the following paragraph for Kynar
- 500(R)/Hylar 5000(R) fluoropolymer finish.
-
- B. Submit manufacturer's standard 20 year finish warranty
- for color retention, adhesion, and freedom from chalking.
-
- C. Submit 2 year weathertightness and workmanship warranty
- from installer.
-
-
- PART 2 PRODUCTS
-
- 2.1 MANUFACTURERS
-
- A. Design is based on products manufactured by ATAS
- International, Inc., 6612 Snowdrift Road, Allentown, PA
- 18106. ASD. Tel: 610-395-8445.
-
- B. Provide panels, anchor clips, closures, flashings, and
- accessories manufactured by a single manufacturer.
-
- C. Substitutions: Comply with procedural requirements of
- Section 01600.
- NOTE ** Delete the following sub-paragraphs if Section
- 01600 defines the limitations on and procedures for
- substitutions. Substitution requirements may also
- be specified in the Instructions to Bidders.
- 1. Requests for substitution of alternate systems must
- be made in writing at least 10 days prior to bid
- date.
- 2. Submit complete product and test data as specified
- under Submittals for each proposed substitution.
-
- 2.2 MATERIALS
-
- A. Precoated Galvanized Steel Sheet: ASTM A 755/A 755M;
- ASTM A 653/A 653M, Structural Quality Grade 33/230, G90/
- Coating Designation, precoated with Kynar 500(R)/Hylar
- 5000(R) finish.
-
- B. Aluminum Sheet: ASTM B 209, minimum yield strength
- 17,000 psi (117 MPa). Prefinish as specified under panel
- type.
- NOTE ** Delete any of the following aluminum finish
- descriptions that are not used on the project.
- 1. Clear Anodic Coating: AAM12C22A41 clear anodized
- coating complying with AAMA 607.1, 0.7 mil thickness
- minimum.
- 2. Color Anodic Coating: AAM12C22A44 coating
- electrolytically deposited and complying with AAMA
- 608.1, 0.7 mil thickness minimum.
-
- C. Copper Sheet: ASTM B 370.
- NOTE ** Delete finishes below not required by panel systems
- specified.
-
- D. Fluoropolymer Coating: Provide multi-coat PVDF Kynar
- 500(R)/Hylar 5000(R) finish system on exposed metal
- surfaces.
-
- E. Siliconized Polyester Coating: Manufacturer's standard
- coating system, factory-applied.
-
- 2.3 PANEL SYSTEMS
-
- A. Roof Panel Systems: Provide factory-formed metal panel
- systems with continuous interlocking panel connections
- and all necessary components to ensure a weathertight
- installation, including but not limited to ridges, hips,
- valleys, eaves, rakes, corners, and miscellaneous
- flashing.
- NOTE ** Select system desired and choose appropriate
- options under each panel type.
- NOTE **
- NOTE ** The Multi-Purpose Panels below successfully
- renovate industrial, commercial, and professional
- buildings and prove excellent for new construction
- as well. The 17 different profiles offered all
- present a sleek, smooth appearance, with a positive
- locking feature and no exposed fasteners. FAXCAT
- Code #1035
-
- B. Multi-Purpose Panel System:
- 1. Material: 0.032 inch (0.81 mm) aluminum.
- 2. Material: 0.040 inch (1.0 mm) aluminum.
- 3. Material: 24 gage (0.61 mm) G90 galvanized steel.
- 4. Width: 8-inch (203 mm) panels.
- a. Profile: Narrow Seam Batten: MPN080.
- b. Profile: Wide Batten: MPW080.
- c. Profile: Board Batten: MPH080.
- d. Profile: Vee Batten: MPV080.
- 5. Width: 12-inch (305 mm) panels.
- a. Profile: Narrow Seam Batten: MPN120.
- b. Profile: Wide Batten: MPW120.
- c. Profile: 5 inch (127 mm) Board Batten: MPH125.
- d. Profile: 7 inch (178 mm) Plank Batten: MPH127.
- e. Profile: 5 inch (127 mm) Vee Batten: MPV125.
- f. Profile: 7 inch (178 mm) Vee Batten: MPV127.
- NOTE ** Note: The following profile is not available in
- either 0.040 inch aluminum or 24 gage steel; it is
- 3/8 inch in overall depth.
- g. Profile: Vee Groove: MPS120.
- 6. Width: 16-inch (406 mm) panels.
- a. Profile: Narrow Seam Batten: MPN160.
- b. Profile: Wide Batten: MPW160.
- c. Profile: 5 inch (127 mm) Board Batten: MPH165.
- d. Profile: 7 inch (178 mm) Plank Batten: MPH167.
- e. Profile: 5 inch (127 mm) Vee Batten: MPV165.
- f. Profile: 7 inch (178 mm) Vee Batten: MPV167.
- NOTE ** Delete one of the following two paragraphs: 1-1/4
- inch depth applies to all types except MPS120; 1/2
- inch applies to MPS120.
- 7. Panel Depth: 1-1/4 inches (32 mm).
- 8. Panel Depth: 1/2 inch (13 mm).
- NOTE ** Panel lengths are cut to customer specifications
- and can range from 2 feet to any transportable
- length.
- NOTE **
- NOTE ** Note: For panel lengths over 25 feet, the Monarch
- Panel is recommended because of its clip
- installation system, which allows the panel to
- "float" for thermal expansion and contraction
- without distortion.
- 9. Panel Length: As indicated on drawings.
- 10. Panel Length: ___________________.
- 11. Texture: Smooth.
- 12. Texture: Stucco Embossed.
- 13. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- 14. Finish: Clear Anodized.
- 15. Finish: Bronze Anodized.
- NOTE ** The Metafor wall panel is applicable to renovations
- and new construction and can be applied directly to
- wood or metal framing. The panel is 12 inches wide
- and has four ribs spaced 3 inches on center. Each
- rib is 1-1/2 inches wide by 5/8 inch deep,
- providing a consistent overall ribbed texture.
- FAXCAT Code #1035
-
- C. Metafor Panel System (MFP120):
- 1. Material: 0.032 inch (0.81 mm) aluminum.
- 2. Material: 0.040 inch (1.0 mm) aluminum.
- 3. Material: 0.050 inch (1.29 mm) aluminum.
- 4. Panel Width: 12 inch (305 mm) coverage.
- 5. Panel Depth: 5/8 inch (16 mm).
- NOTE ** Note: Panel length may vary from 2 feet to any
- transportable length.
- 6. Panel Length: As indicated on drawings.
- 7. Panel Length: _______________.
- 8. Texture: Smooth.
- 9. Texture: Stucco Embossed.
- 10. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- 11. Finish: Clear Anodized.
- 12. Finish: Bronze Anodized.
- NOTE ** The Arc-Metafor system consists of standard Metafor
- panels that have been custom formed to either a
- concave or convex shape. Common applications are
- mansard profiles or curved fascias and soffits.
- FAXCAT Code #1036
-
- D. Arc Metafor Panel System:
- 1. Profile: Concave: MFV120.
- 2. Profile: Convex: MFX120.
- 3. Material: 0.032 inch (0.81 mm) aluminum.
- 4. Panel Width: 12 inch (305 mm) coverage.
- 5. Panel Depth: 5/8 inch (16 mm).
- NOTE ** Note: Minimum concave radius is 4 feet; minimum
- convex radius is 2 feet, 9 inches.
- 6. Panel Radius: As indicated on drawings.
- 7. Panel Radius: _______________.
- 8. Texture: Smooth.
- 9. Texture: Stucco Embossed.
- 10. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- 11. Finish: Clear Anodized.
- 12. Finish: Bronze Anodized.
- NOTE ** The Opaline panel is a very practical system,
- offering profiles that look extruded but are more
- economically rollformed. Panels are installed in a
- basic tongue and groove system with mechanical
- fasteners that are hidden by subsequent panels.
- FAXCAT Code #1036
-
- E. Opaline Panel System:
- 1. Material: 0.032 inch (0.81 mm) aluminum.
- 2. Material: 0.040 inch (1.0 mm) aluminum.
- 3. Material: 24 gage (0.61 mm) G90 galvanized steel.
- 4. Width: 4 inch (100 mm) panels.
- a. Profile: Flush: OPF040.
- b. Profile: 1-inch (25 mm) Rib: OPN041.
- c. Profile: Curved: OPV040.
- 5. Width: 4-1/2 inch (114 mm) panels.
- a. Profile: Ribbed: OPM045.
- b. Profile: Flush with 1/2-inch (13 mm) Reveal:
- OPW045.
- c. Profile: Curved with 1/2-inch (13 mm) Reveal:
- OPV045.
- 6. Width: 6 inch (150 mm) panels.
- a. Profile: Flush: OPF060.
- b. Profile: 1-inch (25 mm) Rib: OPN061.
- 7. Width: 6-1/2 inch (165 mm) panels.
- a. Profile: Flush with 1/2-inch (13 mm) Reveal:
- OPW065.
- 8. Width: 8 inch (203 mm) panels.
- a. Profile: Flush: OPF080.
- b. Profile: 1-inch (25 mm) Rib: OPN081.
- 9. Width: 8-1/2 inch (216 mm) panels.
- a. Profile: Flush with 1/2-inch (13 mm) Reveal:
- OPW085.
- 10. Panel Depth: 3/4 inch (13 mm).
- 11. Panel Length: As indicated on drawings.
- 12. Panel Length: ___________________.
- 13. Texture: Smooth.
- 14. Texture: Stucco Embossed.
- 15. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- 16. Finish: Clear Anodized.
- 17. Finish: Bronze Anodized.
- NOTE ** The PC Systems are two piece systems, consisting of
- a pan and a snapped-on standing seam or batten.
- Battens are available in heights of 1 inch and 2
- inches, and the standing seam is 1-1/4 inches tall.
- These systems are not structural and must be
- installed over solid underlayment. FAXCAT Code
- #1037
-
- F. PC Standing Seam and Batten Style System:
- 1. Material: 0.032 inch (0.81 mm) aluminum.
- 2. Material: 0.040 inch (1.0 mm) aluminum.
- 3. Material: 24 gage (0.61 mm) G90 galvanized steel.
- 4. Pan Width: 11-1/4 inches (286 mm): PCP110.
- 5. Pan Width: 12-5/8 inches (321 mm): PCP120.
- 6. Pan Width: 15-1/4 inches (387 mm): PCP150.
- 7. Pan Width: _____________: PCP999.
- 8. Cap Type: 1-1/4 inch (32 mm) standing seam: PCS114.
- 9. Cap Type: 1-inch (25 mm) high by 1-1/2 inch (38 mm)
- wide batten: PCB001; adds 1-1/4 inch (32 mm) to pan
- dimension for on center dimension.
- 10. Cap Type: 2-inch (50 mm) high by 1-1/2 inch (38 mm)
- wide batten: PCB002; adds 1-1/2 inch (38 mm) to pan
- dimension for on center dimension.
- 11. Panel Length: As indicated on drawings.
- 12. Panel Length: ___________________.
- 13. Texture: Smooth.
- 14. Texture: Stucco Embossed.
- 15. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- 16. Finish: Clear Anodized.
- 17. Finish: Bronze Anodized.
- NOTE ** The Field-Lok Seam system is a standing seam system
- that requires field seaming equipment. Fastening
- is by means of clips concealed within the seams;
- either fixed or expansion type clips can be used,
- depending on project conditions. FAXCAT Code #1037
-
- G. Field-Lok Seam System:
- 1. Material: 0.032 inch (0.81 mm) aluminum.
- 2. Material: 0.040 inch (1.0 mm) aluminum.
- 3. Material: 24 gage (0.61 mm) G90 galvanized steel.
- 4. Panel Width: 12-3/4 inches (318 mm): FLS127.
- 5. Panel Width: 16-3/4 inches (425 mm): FLS167.
- 6. Panel Width: 21 inches (533 mm): FLS210.
- 7. Leg Height: 1-1/2 inches (38 mm).
- 8. Seam Type: Single lock, field crimped.
- 9. Seam Type: Double fold, field locked.
- 10. Installation Clips: Fixed type: FLS900.
- 11. Installation Clips: Expansion type: FLS904.
- 12. Panel Length: As indicated on drawings.
- 13. Panel Length: ___________________.
- 14. Texture: Smooth.
- 15. Texture: Stucco Embossed.
- 16. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- 17. Finish: Clear Anodized.
- 18. Finish: Bronze Anodized.
- NOTE ** Monarch Roof Panels are one-piece components with
- an integral seam that conceals the fasteners and
- clips used for installation. Available in 3
- distinct profiles, Monarch panels have achieved UL
- 90 ratings for wind uplift. ASTM E 330 (modified)
- water and air infiltration tests have also been
- conducted. FAXCAT Code #1038
- NOTE **
- NOTE ** Note: MRC and MRD panels are not available in
- 0.050 inch aluminum. Availability of 22 gage steel
- and copper is subject to minimum quantities and
- adequate lead time.
-
- H. Monarch Roof Panels:
- 1. Material: 0.032 inch (0.81 mm) aluminum.
- 2. Material: 0.040 inch (1.0 mm) aluminum.
- 3. Material: 0.050 inch (1.29 mm) aluminum.
- 4. Material: 24 gage (0.61 mm) G90 galvanized steel.
- 5. Material: 22 gage (0.76 mm) G90 galvanized steel.
- 6. Material: 16 ounce (0.56 mm) copper.
- 7. Material: 20 ounce (0.69 mm) copper.
- 8. Panel Style: Batten.
- a. Width: 12 inches (305 mm): MRB120.
- b. Width: 16 inches (406 mm): MRB160.
- c. Panel depth: 2 inches (50 mm).
- d. Provide stiffening ribs.
- e. Without stiffening ribs.
- 9. Panel Style: Step Seam.
- a. Width: 12 inches (305 mm): MRC120.
- b. Width: 16 inches (406 mm): MRC160.
- c. Panel depth: 2-1/2 inches (63 mm).
- d. Provide stiffening ribs.
- e. Without stiffening ribs.
- 10. Panel Style: Dutch Seam.
- a. Width: 11 inches (279 mm): MRD110.
- b. Width: 15 inches (381 mm): MRD150.
- c. Width: 19-1/4 inches (489 mm): MRD194.
- d. Panel depth: 1-1/2 inches (38 mm).
- e. Provide stiffening ribs.
- f. Without stiffening ribs.
- 11. Panel Length: As indicated on drawings.
- 12. Panel Length: ___________________.
- 13. Texture: Smooth.
- 14. Texture: Stucco Embossed.
- 15. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- 16. Finish: Clear Anodized.
- 17. Finish: Bronze Anodized.
- NOTE ** ScanRoof is a metal "tile panel" that simulates the
- appearance of clay/concrete tile. An integral
- purlin gives structural integrity. Its light
- weight and high load bearing properties allow
- maximum spacing between trusses or reduction of
- roof truss dimensions, up to 4 feet on center, when
- compared to clay tile. FAXCAT Code #1040
-
- I. ScanRoof Tile Panel System - SCP163:
- 1. Material: 24 gage (0.61 mm) G90 galvanized steel.
- 2. Panel Size: 13 feet, 10 inches (4216 mm) by 21
- inches (533 mm).
- 3. Exposure: 13 feet, 2 inches (4013 mm) by 16-1/2
- inches (419 mm).
- 4. Texture: Scalloped tile configuration, 7-7/8 inch
- (200 mm) repeat pattern.
- 5. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- NOTE ** The Techo Tile System is a vertical panel with a
- pattern that simulates Spanish tile. Panels are 5
- "tiles" in width and 3 or more in height. FAXCAT
- Code #1040
-
- J. Techo Tile System - SCT400:
- 1. Material: 0.032 inch (0.81 mm) aluminum.
- 2. Material: 24 gage (0.61 mm) G90 galvanized steel,
- stucco embossed.
- 3. Panel Width: 42 inches (1067 mm) overall, 40 inches
- (1016 mm) exposed.
- NOTE ** Size of each "tile" on a Techo Tile panel is 8
- inches in width and 14 inches in length. The panel
- can be produced to lengths that are multiples of
- the tile length, with a minimum of 3 tiles, or 42
- inches. Stock length is 10 tiles high.
- 4. Panel Length: _________________.
- 5. Panel Depth: 2-1/8 inches (54 mm).
- 6. Pattern: Tile pattern, 0.576 inch (14.6 mm) step per
- tile.
- 7. Texture: Traditional (matte).
- 8. Texture: Glazed (smooth).
- 9. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- NOTE ** Granutile is a metal panel in a tile configuration
- coated with colored stone granules and sealed with
- a clear polymer.
-
- K. Granutile System - HST144:
- 1. Material: 26 gage (0.45 mm) G90 galvanized steel.
- 2. Panel Width: 16 inches (406 mm), 14-1/2 inches (368
- mm) exposed.
- 3. Panel Length: 46 inches (1168 mm), 43-3/4 inches
- (1111 mm) exposed.
- 4. Pattern: Tile pattern, 7 tile repeat.
- 5. Texture: Granular.
- 6. Finish: Stone granules coated with clear polymer.
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's 6 standard colors.
- c. Color: ___________________.
- NOTE ** Standing Seam Shingles give the appearance of the
- traditional standing seam, with the handling ease
- of 36 inch or 60 inch long panels. A four-way
- interlock insures weathertightness.
-
- L. Standing Seam Shingle System:
- 1. Material: 28 gage (0.47 mm) galvanized steel.
- 2. Material: 16 oz/sf (0.56 mm) copper, natural color.
- 3. Panel Width: 16 inches (406 mm).
- 4. Panel Length: 36 inches (915 mm): HSS163.
- 5. Panel Length: 60 inches (1524 mm): HSS166.
- 6. Texture: Smooth.
- 7. Finish: Ceram-a-Star(tm)950.
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's 6 standard colors.
- c. Color: ___________________.
- NOTE ** Permashake panels simulate the look of wood grained
- shingles. The four-way interlocking panels are
- fastened with an anchor clip and lock system.
-
- M. Permashake System - HSP106:
- 1. Material: 28 gage (0.47 mm) G90 galvanized steel.
- 2. Panel Width: 10 inches (254 mm).
- 3. Panel Length: 60 inches (1524 mm).
- 4. Texture: Simulated shake.
- 5. Finish: Ceram-a-Star(tm)950.
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's 4 standard colors.
- c. Color: ___________________.
- NOTE ** CastleTop is a diamond shaped flat metal tile with
- an expanded polystyrene backer board. The backer
- gives strength to the panel, serves as an
- insulator, and aids in noise reduction. The turned
- down edge on the front and the turned up edge on
- the back give double sealing protection against the
- weather.
-
- N. CastleTop System - HSC160:
- 1. Material: 0.032 inch (0.81 mm) thick aluminum.
- 2. Material: 16 oz/sf (0.56 mm) copper, natural color.
- 3. Material: 0.020 inch (0.51 mm) thick zinc, natural
- color.
- 4. Panel Size: 16 inches (406 mm) by 16 inches (406
- mm), 14 inches (355 mm) by 14 inches (355 mm)
- exposed.
- 5. Texture: Smooth.
- 6. Texture: Embossed.
- 7. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- NOTE ** The Belvedere system is a structural wall panel in
- three different styles, offering design freedom for
- all types of buildings. It can be installed either
- on a solid substrate or on spaced framing. FAXCAT
- Code #1036
-
- O. Belvedere Wall Panel System:
- 1. Profile: Span Wall - BWS240.
- a. Material: O.032 inch (0.81 mm) aluminum,
- embossed.
- b. Material: 0.040 inch (1.0 mm) aluminum, smooth.
- c. Material: 0.040 inch (1.0 mm) aluminum,
- embossed.
- d. Material: 0.050 inch (1.29 mm) aluminum, smooth.
- e. Material: 0.050 inch (1.29 mm) aluminum,
- embossed.
- f. Material: 24 gage (0.61 mm) G90 galvanized
- steel, embossed.
- g. Panel width: 24 inches (610 mm).
- h. Panel depth: 4 inches (100 mm).
- 2. Profile: Box Panel - BWB360.
- a. Material: 0.032 inch (0.81 mm) aluminum,
- embossed.
- b. Material: 0.040 inch (1.0 mm) aluminum, smooth.
- c. Material: 0.040 inch (1.0 mm) aluminum,
- embossed.
- d. Material: 0.050 inch (1.29 mm) aluminum, smooth.
- e. Material: 0.050 inch (1.29 mm) aluminum,
- embossed.
- f. Panel width: 36 inches (915 mm).
- g. Panel depth: 4 inches (100 mm).
- 3. Profile: Rib Panel - BWR360.
- a. Material: 0.032 inch (0.81 mm) aluminum, smooth.
- b. Material: 0.032 inch (0.81 mm) aluminum,
- embossed.
- c. Material: 0.040 inch (1.0 mm) aluminum, smooth.
- d. Material: 0.040 inch (1.0 mm) aluminum,
- embossed.
- e. Material: 0.050 inch (1.29 mm) aluminum, smooth.
- f. Material: 0.050 inch (1.29 mm) aluminum,
- embossed.
- g. Material: 24 gage (0.61 mm) G90 galvanized
- steel, smooth.
- h. Material: 24 gage (0.61 mm) G90 galvanized
- steel, embossed.
- i. Material: 22 gage (1.0 mm) G90 galvanized steel,
- smooth.
- j. Material: 22 gage (1.0 mm) G90 galvanized steel,
- embossed.
- k. Panel width: 36 inches (915 mm).
- l. Panel depth: 1-1/2 inches (38 mm).
- NOTE ** Panel lengths for all Belvedere systems are cut to
- customer specifications, from 4 feet minimum (Span
- Wall 9 feet minimum) to 40 feet maximum.
- 4. Panel Length: _________________.
- 5. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- NOTE ** The Design Wall system consists of a 12 inch wide
- panel in a choice of two distinct profiles - a
- smooth panel with stiffening ribs and a "board"
- panel. The "board" panel has an up side of 6
- inches which may be extended in 1 inch increments.
- For every 1 inch increase in the width of the
- "board", the lower part of the panel increases
- equally, to give an overall coverage of up to 12
- inches. FAXCAT Code #1036
-
- P. Design Wall System:
- 1. Material: 0.032 inch (0.81 mm) aluminum.
- 2. Material: 0.040 inch (1.0 mm) aluminum.
- 3. Material: 0.050 inch (1.29 mm) aluminum.
- 4. Material: 24 gage (0.61 mm) G90 galvanized steel.
- 5. Panel Width: 12 inches (305 mm).
- 6. Panel Style: Provide stiffening ribs.
- 7. Panel Style: Without stiffening ribs.
- a. Panel depth: 1-3/4 inches (44 mm): DSF120.
- b. Panel depth: 1-1/8 inches (29 mm): DWF120.
- 8. Panel Profile: Board type, with adjacent recess and
- stiffening ribs.
- 9. Panel Profile: Board type, with adjacent recess and
- without stiffening ribs.
- a. Panel depth: 1-3/4 inches (44 mm): DSH120.
- b. Panel depth: 1 inch (25 mm): DWH120.
- c. Board width: 6 inches (152 mm).
- d. Board width: 7 inches (178 mm).
- e. Board width: 8 inches (203 mm).
- f. Board width: 9 inches (229 mm).
- g. Board width: 10 inches (254 mm).
- h. Board width: 11 inches (279 mm).
- 10. Panel Length: As indicated on drawings.
- 11. Panel Length: ___________________.
- 12. Texture: Smooth.
- 13. Texture: Stucco Embossed.
- 14. Finish: Kynar 500(R)/Hylar 5000(R).
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
- NOTE ** The following is available only in 0.032 inch
- aluminum.
- 15. Lanced: Provide vented panels where indicated.
- NOTE ** Linear Ceiling is available in two distinct
- profiles - round edge and a square box style panel,
- with or without filler strips. Each profile has a
- choice of three widths that are interchangeable due
- to the 4 inch module of the carrier system. FAXCAT
- Code #1039
-
- Q. Linear Ceiling System:
- 1. Style: Round edge: LCR.
- 2. Style: Box edge: LCB.
- 3. Texture: Smooth.
- 4. Panel Width: 4 inch (100 mm) nominal.
- 5. Panel Width: 8 inch (203 mm) nominal.
- 6. Panel Width: 12 inch (305 mm) nominal.
- 7. Panel Depth: 5/8 inch (16 mm).
- 8. Material: 0.032 inch (0.81 mm) aluminum.
- a. Finish: Kynar 500(R)/Hylar 5000(R).
- b. Finish: Clear anodized.
- c. Finish: Bronze anodized.
- d. Color: As indicated on the drawings.
- e. Color: As selected by Architect from
- manufacturer's standard colors.
- f. Color: ___________________.
- 9. Material: 0.020 inch (0.51 mm) aluminum.
- 10. Material: 0.025 inch (0.64 mm) aluminum.
- a. Finish: Siliconized polyester coating.
- b. Color: As indicated on the drawings.
- c. Color: As selected by Architect from
- manufacturer's standard colors.
- d. Color: ___________________.
- 11. Closing Strip: Flush (with LCR Series only).
- 12. Closing Strip: Recessed.
- NOTE ** The Wind-Lok(TM) panel system has been around for
- years and is still the best of its type. These
- panels can be used for wide overhangs and ceilings
- both indoors and out. The Wind-Lok(TM)
- installation method results in no exposed
- fasteners, and the panels are available in 6
- standard colors. Unlike the tongue and groove
- method, the panels are hooked into each other,
- which prevents the panels from sagging in the
- middle, or slipping apart on wide ceilings. FAXCAT
- Code #1039
-
- R. Wind-Lok(tm) Soffit Panel System:
- 1. Material: 0.019 inch (0.48 mm) aluminum, smooth.
- 2. Material: 0.024 inch (0.61 mm) aluminum, smooth.
- 3. Panel Style: Smooth: WLS120.
- 4. Panel Style: Vented: WLV120.
- 5. Panel Width: 12 inches (305 mm).
- 6. Panel Depth: 7/16 inch (11 mm).
- 7. Panel Length: ______________.
- 8. Finish: Siliconized polyester.
- a. Color: As indicated on the drawings.
- b. Color: As selected by Architect from
- manufacturer's standard colors.
- c. Color: ___________________.
-
- 2.4 ACCESSORIES
-
- A. Provide formed accessories of same gage and finish as the
- primary panel system, unless otherwise indicated on the
- drawings.
-
- B. Anchor Clips: Concealed type, designed to allow for
- thermal movement of panels.
-
- C. Sealants: As specified in Section 07900.
-
- D. Fasteners: As recommended by manufacturer for project
- conditions and panel type.
-
- 2.5 FABRICATION
-
- A. Panels: Factory-fabricate all panels with integral lock
- and seam design.
- NOTE ** Delete the following paragraph if the panel type
- specified is not available in 70 foot lengths.
-
- B. Fabricate panels up to 70 feet (21 m) long in one piece
- without transverse seams. Panels over 70 feet (21 m)
- long may be fabricated with seams; use manufacturer's
- standard end lap details.
-
- C. Factory-fabricate trim and flashing components in minimum
- 12 foot (3.65 m) lengths, with allowance for thermal
- movement in joint design.
-
- D. Form all components true to shape, accurate in size,
- square and free from distortion or defects. Cut panels
- to precise lengths indicated on approved shop drawings.
-
-
- PART 3 EXECUTION
-
- 3.1 EXAMINATION
-
- A. Inspect substrates to verify that they are in proper
- condition, spaced correctly, plumb, and are ready to
- receive panels and accessories.
- 1. Notify the Architect in writing if substrates are not
- suitable for application of panel system.
- 2. Do not proceed with installation until substrates are
- acceptable.
-
- B. Verify actual dimensions in field prior to ordering
- materials.
-
- 3.2 INSTALLATION
-
- A. Install metal panels and accessories in strict accordance
- with manufacturer's instructions and applicable codes.
-
- B. Protect surfaces in contact with cementitious materials
- and dissimilar metals with bituminous paint.
-
- C. Fasten panels to structural supports with concealed
- anchor clips, except where fixed attachment points are
- indicated. Install panels plumb, level, and true to
- line.
-
- D. Fully interlock panels with adjacent panels; apply
- sealants as recommended by panel manufacturer to achieve
- weathertight installation.
- NOTE ** Delete paragraph below if no roof panels are
- required for project, or if ScanRoof or Techo Tile
- roofing systems are specified.
-
- E. Install roof panels with no transverse seams.
-
- F. Do not allow shavings, metal dust, or chips to fall on
- panels.
-
- 3.3 ADJUSTING AND CLEANING
-
- A. Remove all protective masking from material immediately
- after installation.
-
- B. Touch up minor abrasions with matching paint provided by
- panel manufacturer. Remove and replace panels that
- cannot be satisfactorily touched up.
-
- C. Sweep and remove chips, shavings, and dust from roof on a
- daily basis during installation period. Leave installed
- work clean, free from grease, finger marks and stains.
-
- D. Upon completion of installation, remove scraps and debris
- from project site.
-
- 3.4 PROTECTION
-
- A. Provide protection as required to assure that completed
- work of this section will be without damage or
- deterioration at date of substantial completion.
-
-
- END OF SECTION
-